CONSOLE
LONG-TERM FILTER
The machine is equipped with a long - lasting purification filter inside, which enables longer purification time and makes the indoor air fresher and healthier.
FREE CHOICE OF BOTTOM AIR OUTLETAND TOP AIR OUTLET
Users can freely choose the air outlet position according to the usage scenario and usage habits.lf you select bottom air outlet, the usage effect is similar to floorheating; if you select top airoutlet, the heating speed is faster than floorheating, making the use effect more comfortable
*AUX reserves the right to interpret the data.
Product Features
LONG-TERM FILTER
The machine is equipped with a long - lasting purification filter inside, which enables longer purification time and makes the indoor air fresher and healthier.
FREE CHOICE OF BOTTOM AIR OUTLETAND TOP AIR OUTLET
Users can freely choose the air outlet position according to the usage scenario and usage habits.lf you select bottom air outlet, the usage effect is similar to floorheating; if you select top airoutlet, the heating speed is faster than floorheating, making the use effect more comfortable
Specifications
ModelModelIndoor
FDCO35-B1
FDCO52-B
Outdoor
RXYL35M-T1B
RXYL52M-T1B
Performance dataOutput power-COOLINGkW3.52(1.35~4.40)4.70(1.53~5.60)
Output power-HEATINGkw3.81(1.24~5.30)5.00(1.40~6.20)
Absorbed power-COOLINGkw1.03(0.26~1.60)1.55(0.47~2.30)
Absorbed power-HEATINGkw1.02(0.19~1.51)1.51(0.46~2.25)
Energy classw/W3.423.03
w/W3.743.31
COOLING PdesignkW3.54.7
HEATING PdesignkW2.73.7
Energy class -AVERAGE6.2(A++)6.1(A++)
4.0(A+)4.0(A+)
Energy class -WARM5.1(A+++)5.2(A+++)
Annual Energy Consumption-COOLINGkWh/a192267
Annual Energy Consumption-HEATINGkWh/a8801247
Indoor UnitPower supplyPh/V/Hz220-240V~,50Hz,1220-240V~,50Hz,1650/5501450
Treated air volumem3/h600/530/430650/550/450
High soundpowerdB5658
Sound pressuredB(A)42/39/3644/40/37
Net dimensionsmm700x225x600700x225x600
Packaging dimensionsmm780x300x675780x300x675
Net/grossweightkg14.5117.514.5/17.5
Outdoor UnitPower supplyPh/V/Hz220-240V~,50Hz,1220-240V~,50Hz,1
Power cableNxmm23*1.53*1.5
Interconnection cableNxmm24*1.04*1.0
Sound powerdB6566
Sound pressuredB(A)5354
Running current cooling/heatingNet A912
Packaging dimensionsmm900x380x615900x380x615
Net/gross weightkg24.5/2728.5/31
Compressor type/ROTARYROTARY
Net dimensionsmm900x380x615900x380x615
Installation dataRefrigerant/R32R32
Liquid pipemm(inch)6.35(1/4)6.35(1/4)
Gas pipemm(inch)9.52(3/8)12.7(1/2)
Standard pipe length without refrigerant chargem55
Maximum pipe lengthm2530
Maximum lU-QUelevationm2530
Refrigerant charge in the factorykg0.751.10
Refrigerant charge in the factoryTC02eq0.510.74
Additional ref,charge over std lengthg/m3030
Outdoor operating limits-COOLINGmin-maX-20~52-20~52
Outdoor operating limits-HEATING-20~24-20~24