VRF

VRF

  • WIDE RANGE CAPACITY
    ARV7-ME single ODU capacity from 8 to 36HP, and the max combination of 4 ODUs is 144HP.
  • LONG PIPING LENGTH
    Max. Level difference between ODU and IDU units:110m/130m.
  • 6-STAGE OIL RETURN CONTROL
    6-stage oil return control technology able to precise control the oil balance,ensure compressor long-term stable operation.
LARGE CAPACITY&FREE COMBINATION
15 basic models from 8HP to 36HP.
Less quantity of system, space saving, easy installation and low cost.
WIDE OPERATION RANGE
No matter in hot summer or cold winter, ARV 7 Series can supply comfortable environment for users.
WIDE VOLTAGE DESIGN
In Country with unstable voltage, ARV system still could run stably.
LONG PIPING LENGTH
Thanks to the DC inverter control technology and sub-cooling circuit technology, it is possible to design a system with longer piping and greater elevation differences, which make it easier to design and install.
PRECISE TEMPERATURE CONTROL
Adopting composite temperature control technology, the set temperature can reach ± 0.5℃.
AUTO RESTART FUNCTION
The AC can automatically memorize the operation setting when power is cut off accidently. it can return to previous setting when power resumes.
Recover the former operation state when power is restored, no need restart the unit manually.
REFRIGERANT PCB COOLING SYSTEM
The PCB is well cooled by the refrigerant, ensuring the system operate steadily even in tropical area.
Frequency limit of inverter compressor can be relaxed, so that the output capacity of ODU can be higher than conventional products.

Specifications

HP 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36
Model ARV-H250/SR1MV-ME ARV-H280/SR1MV-ME ARV-H330/SR1MV-ME ARV-H⁴00/SR1MV-ME ARV-H450/SR1MV-ME ARV-H500/SR1MV-ME ARV-H560/SR1MV-ME ARV-H610/SR1MV-ME ARV-H680/SR1MV-ME ARV-H730/SR1MV-ME ARV-H785/SR1MV-ME ARV-H850/SR1MV-ME ARV-H900/SR1MV-ME ARV-H950/SR1MV-ME ARV-H1010/SR1MV-ME
Power Supply V~Hz,Ph 380~415,50/60,3 380~415,50/60,3 380~415,50/60,3 380~415,50/60,3 380~415,50/60,3 380~415,50/60,3 380~415,50/60,3 380~415,50/60,3 380~415,50/60,3 380~415,50/60,3 380~415,50/60,3 380~415,50/60,3 380~415,50/60,3 380~415,50/60,3 380~415,50/60,3
Capacity Cooling(T1) kW 25.2 27.9 33.3 40.0 45.0 50.0 56.0 61.5 67.0 73.0 78.5 85.0 90.0 95.0 101/0
Btu/h 86000 95000 114000 136000 154000 170000 192000 210000 228000 250000 268000 290000 308000 324000 344000
Cooling(T3) kW 22.2 24.9 29.4 33.6 37.2 42.0 44.0 46.0 52.0 57.0 61.0 63.5 65.0 67.5 71.5
Btu/h 76000 85000 100000 114000 127000 144000 150000 156000 178000 194000 208000 216000 222000 230000 244000
Heating kW 252 27.9 33.3 40.0 45.0 50.0 56.0 61.5 67.0 73.0 78.5 85.0 90.0 95.0 101.0
Btu/h 86000 95000 114000 136000 154000 170000 192000 210000 228000 250000 268000 290000 308000 324000 344000
Electric Data Rated Cooling Power Input(T1) kW 5.99 6.98 8.62 10.67 13.04 13.70 16.14 18.64 19.42 23.17 25.74 28.33 30.20 32.20 34.47
Rated Cooling Power Input(T3) kW 7.55 9.02 10.24 11.62 13.73 15.73 17.05 18.4 20 22.35 24.4 25.6 26.53 27.89 29.79
Rated Heating Power Input(T1) kW 4.8 5.5 6.6 8.5 9.8 12.2 13.83 17.6 16.8 19.1 21.8 24.3 26.5 28.4 30.4
Performance EER(T1) W/W 4.20 4.00 3.85 3.75 3.45 3.65 3.45 3.30 3.45 3.15 3.05 3.00 2.98 2.95 2.93
Btu/(h*W) 14.35 13.65 13.15 12.80 11.80 12.45 11.80 11.25 11.75 10.80 10.40 10.25 10.20 10.05 10.00
EER(T3) W/W 2.95 2.75 2.85 2.90 2.70 2.65 2.60 2.50 2.60 2.55 2.50 2.48 2.45 2.42 2.40
Btu/(h*W) 10.05 9.40 9.75 9.90 9.20 9.05 8.85 8.55 8.90 8.70 8.50 8.45 8.35 8.25 8.20
COP(T1) W/W 5.25 5.07 5.05 4.71 4.59 4.10 4.05 3.49 4.00 3.80 3.60 3.50 3.40 3.35 3.30
Refrigerant type Type R410a R410a R410a R410a R410a R410a R410a R410a R410a R410a R410a R410a R410a R410a R410a
Compressor Quantity 1 1 1 2 1 2 2 2 2 2 2 2 2 2 2
Type DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter
Fan motor Type DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter
Quantity 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2
Air Flow Volume CFM 7059 7059 7059 8235 8235 9412 9412 9412 17059 17059 17059 17647 17647 17647 17647
m3/h 12000 12000 12000 14000 14000 16000 16000 16000 29000 29000 29000 30000 30000 30000 30000
Sound Pressure level dB(A) 58 58 58 61 61 63 63 63 62 62 63 63 64 66 66
Dimension
(W×D×H)
Net mm 990×765×1635 990×765×1635 990×765×1635 1340×765×1635 1340×765×1635 1340×765×1635 1340×765×1635 1340×765×1635 1850×825×1760 1850×825×1760 1850×825×1760 1850×825×1760 1850×825×1760 1850×825×1760 1850×825×1760
Packing mm 1030×825×1865 1030×825×1865 1030×825×1865 1395×815×1865 1395×815×1865 1395×815×1865 1395×815×1865 1395×815×1865 1925×930×1930 1925×930×1930 1925×930×1930 1925×930×1930 1925×930×1930 1925×930×1930 1925×930×1930
Weight Net kg 215 215 230 265 265 330 330 330 388 388 388 422 422 430 430
Gross kg 225 225 240 280 280 345 345 345 411 411 411 445 445 453 453
Piping limitations Max.Length m 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
Max.Height m 110/130 110/130 110/130 110/130 110/130 110/130 110/130 110/130 110/130 110/130 110/130 110/130 110/130 110/130 110/130
Ambient Temp(Cooling/Heating) ℃ -10~55/-20~24 -10~55/-20~24 -10~55/-20~24 -10~55/-20~24 -10~55/-20~24 -10~55/-20~24 -10~55/-20~24 -10~55/-20~24 -10~55/-20~24 -10~55/-20~24 -10~55/-20~24 -10~55/-20~24 -10~55/-20~24 -10~55/-20~24 -10~55/-20~24
Your Information

It's so nice to meet you! Upon receiving your completed form, we will contact you as soon as possible to arrange a complimentary consultation at your convenience.

Full Name
Contact Number
+971
Email
Inquiry Type
-- Select --
Homeowner
Contractor
Distributor
State
{{ stateValue || '-- Select --' }}
City
{{ cityValue || '-- Select --' }}
Message
*I have read and agree to AUX's Privacy Policy
Document Filter
Official Global Partner
* By entering your email address, you agree to receive our electronic newsletters in accordance to our Privacy Policy, which you can unsubscribe at anytime.
We are sorry for your departure...
We sincerely hope that you will continue to subscribe and follow the latest developments on your aux.